Philips Ultrasound, Inc recalls Philips X3-1 Ultrasound Transducer
Reason for recall
To provide clarification and labelling to define the useful life of ultrasound transducers in the field.
Affected product
Check your device
Enter a lot, serial, REF, or UDI number from your device's label to check it against this recall's listed codes.
Philips X3-1 Ultrasound Transducer
Lot / code information
- Model
- 989605440742, 989603002321, 989605388101, 989605440741
- UDI
(01)00884838067615(21)033TVZ, (01)00884838067615(21)02Q8R3, (01)00884838067615(21)02VLZV, (01)00884838067615(21)02WND0, (01)00884838067615(21)02ZWBH, (01)00884838067615(21)02GP3C — +8 moreShow all
(01)00884838067615(21)033TVZ, (01)00884838067615(21)02Q8R3, (01)00884838067615(21)02VLZV, (01)00884838067615(21)02WND0, (01)00884838067615(21)02ZWBH, (01)00884838067615(21)02GP3C, (01)00884838067615(21)03DTL6, (01)00884838067615(21)02JK1H, (01)00884838067615(21)02VMJ6, (01)00884838067615(21)035Z89, (01)00884838067615(21)031C21, (01)00884838067615(21)02JL3W, (01)00884838067615(21)03C066, (01)00884838067615(21)02JK8D- Serial #
- 033TVZ, 02Q8R3, 02VLZV, 02WND0, 02ZWBH, 02GP3C, 02YHTG, 02YHPN, 03DTL6, 02JK1H, 02VMJ6, 035Z89, 031C21, 038NQC, 02JL3W, 03C066, 02JK8D
What the firm is doing
An URGENT Medical Device Correction Notice, dated 8/19/25, was mailed to consignees. This notice instructs consignees to locate all Philips Ultrasound transducers in their facility and enter their serial numbers into https://www.transducer.philips.com to obtain the manufacturing certificate for each of their devices. This certificate should be retained with its system documentation. Using the manufacturing certificate consignees are to calculate the useful life of their device. The expected useful life for Transesophageal transducers, X-Matrix transducers, and Lumify transducers is 5 years; The expected useful life for Endocavity transducers and Transcutaneous transducers is 7 years. If a transducer has exceeded its useful life, consignees are instructed to conduct transducer performance tests or contact Philips for guidance. Consignees are asked to complete and return the provided response form and circulate the recall notification to device users for their awareness. Consignees with any questions can contact Philips Customer Care Solutions Center at 1-800-722-9377.
DistributionShow detailsHide
US Nationwide distribution.
Use of the product is not likely to cause adverse health consequences.
Sources & references
- FDA enforcement recordOfficial FDA database entry for Z-1627-2026
- FDA 510(k) clearance · K042540The device's official FDA premarket clearance record
- FDA device classification · ITXOfficial FDA classification for this device type
- CFR regulation · 21 CFR 892.1570The federal regulation governing this device
- FDA recall announcementSearch FDA.gov for the official press announcement
- Find Philips Ultrasound, IncSearch for the manufacturer's official notice
- News coverageRecent reporting on this recall and manufacturer
- openFDA data recordThe raw JSON record this page is built from
Source: U.S. FDA openFDA device enforcement reports. This summary is informational and may lag or differ from the official record. Always verify against the FDA before acting.
Taylor Coteus is RecallWatch's Legal News Analyst, covering FDA medical-device enforcement and patient-safety litigation. He reviews every recall against the FDA's official openFDA record before it is published and is responsible for corrections and editorial accuracy.
More Class III recalls
HeartSine Technologies Ltd recalls HeartSine samaritan PAD (Public Access Defibrillator)
Products were distributed without the required Maintenance Supplement, which describes an extra check every 3 months in addition to the monthly check.
- Automated External Defibrillators (Non-Wearable)
- Process control
Paragon 28, Inc. recalls Custom Made Device Implant 6123 Navicular Cage Nominal Right Rev A
Device was recalled due to an elevated oxygen level in excess of the allowable limit. Elevated oxygen levels may contribute to reduced material ductility.
- Bone Wedge
- Under Investigation by firm
Paragon 28, Inc. recalls Custom Made Device Implant 6123 Navicular Cage Small Right Rev A
Device was recalled due to an elevated oxygen level in excess of the allowable limit. Elevated oxygen levels may contribute to reduced material ductility.
- Bone Wedge
- Under Investigation by firm