Skip to content
RecallWatchMedical Device Safety
Class IIOngoingZ-1921-2026

Windstone Medical Packaging, Inc. recalls Custom Convenience Kits Pre Op Kit - NS

Windstone Medical Packaging, Inc.Billings, MT, United StatesReported Apr 29, 2026 · 2 months ago
Legal News Analyst ·

Reason for recall

The product correction was initiated because B Braun is issuing a voluntary Urgent Medical Device Correction for gravity IV administration sets as well as pump administration sets utilized with BBMI s Infusomat Space Large Volume Pump, Outlook Pump and Vista Basic Pump due to potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers or other connections and the ability to prime (occlusion).

Affected product

Check your device

Enter a lot, serial, REF, or UDI number from your device's label to check it against this recall's listed codes.

Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14994A

Lot / code information

UDI
B098AMS14994A0
Lot #
224792 228566 230105 230853 234209

What the firm is doing

An URGENT: MEDICAL DEVICE CORRECTION notification letter was sent to customers on 3/11/26. AMS requests that you undertake the following activities: 1. Review your inventory for the affected kits, all lots are impacted. 2. Communicate the notification with all personnel that utilize B Braun Admin. Sets contained within AMS kits. 3. If you have further distributed this product, please identify your distribution partners, and notify them at once of the product notification. Your notification to your customers should include a copy of this notification letter. 4. Please complete and return the AMS Urgent Medical Device Product Notification Response Required form within 5 business days and return via email to fieldcorrectiveaction@alignedmedical.com even if you have no affected product on hand. Please complete the attached AMS Urgent Medical Device Product Notification Response Required form and return it to Aligned Medical Solutions at the Fax number provided on the form. If you do not have the affected product, you must complete and return the form. If you have any questions or concerns, please do not hesitate to contact us at fieldcorrectiveaction@alignedmedicalsolutions.com.

DistributionShow details

US Nationwide distribution in the states of GA, OR, TN, and WA.

Class IIWhat this means

Use of the product may cause temporary or medically reversible adverse health consequences.